A framed wall is a bottom plate, a row of studs, a double top plate and headers over every opening, with blocking and connectors added where the plans call for them. For a typical interior or non-structural exterior wall, studs are 2x4s at 16 inches on center; taller walls, plumbing walls and shear walls change the lumber size, the spacing or the nailing, so always follow your plans and your LA building department's requirements. This guide lists every material you need and links to the Supply Ontime guides for the decisions inside each step.
Studs are the bulk of the order. Supply Ontime carries Douglas fir framing studs in both green and kiln-dried, for example the 2x4x8 #2 & BTR kiln-dried stud and the 2x6x10 #2 & BTR green stud for thicker exterior walls. Kiln-dried lumber shrinks and twists less after it is nailed in place, which matters for wall finishes. The grade stamp on each piece is what an inspector reads; our lumber grade stamps guide decodes it, and the Douglas fir lumber collection has the full range.
| Part | Typical size | Job |
|---|---|---|
| Studs | 2x4 or 2x6 | Vertical framing |
| Bottom plate | Same as stud | Anchors wall to floor |
| Top plates | Doubled | Ties walls together |
| Header | Sized by span | Carries load over openings |
| Blocking | Same as stud | Backing and stiffness |
Cut the bottom plate and top plates to length and mark stud positions on both at once so they match. Layout at 16 inches on center is the common standard, with extra studs at corners, wall intersections and both sides of every opening. On a concrete slab, the bottom plate must be anchored to the slab and is normally pressure-treated; see our pressure-treated vs borate-treated lumber guide and the concrete anchors comparison for the plate and anchor choices.
Every door and window opening needs a header sized for its span and the load above it, supported by jack studs on each side. Header size comes from your plans or a code table, not from a rule of thumb. Header hardware such as the HH4 header hanger can support a 4x header without extra trimmer studs where the design allows it, and keeps the framing simple in tight spaces.
Framing is assembled with 16d-class nails, driven through the plate into each stud end and toe-nailed or face-nailed as the plans specify. Sizes, coatings and collations are covered in our framing nails guide, and the framing nails collection includes collated options such as the 3-1/4 in. x 0.131 in. 21-degree framing nails for a pneumatic framing gun. Use the nail size and pattern your engineer or plans specify; shear walls have strict requirements.
Exterior walls are sheathed with plywood or OSB, and in LA many walls are shear walls with specified panel thickness, edge nailing and blocking. Do not guess these details: read our shear wall sheathing guide and match your plans. Panels like 23/32 in. CDX plywood and 7/16 in. OSB are in the plywood and OSB collection.
Los Angeles walls are tied to the foundation with anchor bolts and, where the plans require them, holdowns at the ends of shear walls. Our seismic holdowns, straps and anchor bolts guide explains the roles, and the holdowns collection carries connectors such as the HDU2 predeflected holdown. Only the engineer's plans decide which holdown goes where.
Choose straight, graded lumber, keep layout consistent at 16 inches on center unless the plans say otherwise, and treat nailing patterns and holdowns as engineered details, not preferences. Confirm every structural item with your plans and your LA building department before you order.